Products
Home ABB ABB A50-30-11 3 POLE Contactor 1SBL351001R8411

ABB A50-30-11 3 POLE Contactor 1SBL351001R8411

A50-30-11 3 POLE Contactor

Contact:cassiebirthdayparty@gmail.com

  • Item NO.:

    ABB A50-30-11
  • Payment:

    T/T
  • Product Origin:

    Sweden
  • Shipping Port:

    HongKong
  • Lead Time:

    3 days
  • Goods Stock:

    10
  • Order(MOQ):

    1
  • Product Detail

ABB A50-30-11 3 POLE Contactor 1SBL351001R8411

Contact:cassiebirthdayparty@gmail.com

SPECIFIC CAUTIONS (continued)
Page 114: It is not possible to change the CI852 unit via hot swap and it is not allowed to perform an online upgrade of firmware in a system containing CI852.
Page 118: Hot swap is supported for CI854A (not CI854).
Page 133: – 115 V for 110–120 V AC – 230 V for 220–240 V AC (default position on delivery).
Page 141: To avoid error indications from SA/SB when single power supply is used, it is recommended to connect the input terminals SA/SB on the CPU to +24 V, see Figure 47.
Page 143: Do not connect the TK821V020 cable until the AC 800M Controller has been powered-up normally and the memory back-up function has been activated, that is, the Battery LED flashes. If no normal power supply is connected to the PM8xx processor unit, the CPU memory will immediately start to consume battery power when the cable is connected.
Page 157: When setting the IP address of the primary CPU in Control Builder, the backup CPU must be turned off (powered down). Otherwise the backup CPU will take over and you get disconnected.
Page 159: Note that the electrical ModuleBus can only be used for connection of S800 I/O when AC 800M is running in single CPU configuration.
Page 184: Note that a Backup CPU with severe communication errors on the ModuleBus will be rejected (if Module Bus is part of the HW configuration) and synchronized state will never be reached as long as error remains.
Page 189: The RCU Link Cable must NEVER be removed from the primary Processor Unit during redundant operation. Removal of the cable may cause the unit to stop.
Page 192: Due to the batteries being connected in parallel, it is necessary,when using the SB821 external battery, to remove the internal battery from the PM8xx in order to avoid reducing available memory back-up time.

ABB A50-30-11 Technical drawing:

ABB IMHSS05


We would be appreciate to receive your inquiry and also here are some other products for your choice:

6ES7963-3AA00-0AA0 1769-OB16 X20ps9500
6ES7331-7NF10-0AB0 1756-L71SK X20tb12
6ES7153-2BA02-0XB0 1734-TOP X20bm11
6ES7134-4NB00-0AB0 1734-OB8S X20di9371
6ES7332-5HF00-0AB0 2711P-RP X20do9322
6ES7151-1BA02-0AB0 1769-PA2 X20ai4622
6ES7138-4CA01-0AA0 2711R-T4T X20at4222

ABB SPHSS05


Why Choose Us?

 Extensive & Real Inventory

Provide Satisfying Discounts

Fully Tested and Guaranteed

 We provide 12 months warranty for all parts and components.Your satisfaction is how we measure success.

 Flexible Payment & Shipment

Unless otherwise specified,we will ship your order via(DHL).We can also ship via Fedex.

Unparalleled Experience & Service

We cooperates with a great number of customers in numerous countries and regions around the world.Our customer support team is always on call to help you with any form of consultation.



Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
Ai815 datasheet
ABB AI815 Analog Input HART 8 ch 3BSE052604R1

Analog Input Module has 8 channels Contact:cassiebirthdayparty@gmail.com

Nmba-01 datasheet
ABB NMBA-01 3BHL000510P0003 Modbus Adapter Module

PLC Processor Module Contact:cassiebirthdayparty@gmail.com

FPBA-01 datasheet
ABB FPBA-01 PROFIBUS DP adapter module

ABB Profibus DP Adapter Module Contact:cassiebirthdayparty@gmail.com

RLM01 3BDZ000398R1 datasheet
ABB RLM01 3BDZ000398R1 PROFIBUS Redundancy Link Module

ABB PROFIBUS Redundancy Link Module Contact:cassiebirthdayparty@gmail.com

INIIT03 datasheet
ABB INIIT03 ABB Bailey Infi 90 Infi-Net Local Transfer Mod

Infinet to Infinet Transfer Module Contact:cassiebirthdayparty@gmail.com

PM864AK01 datasheet
ABB PM864AK01 Classic System 800xA hardware selector 3BSE018161R1

Classic System 800xA hardware selector Contact:cassiebirthdayparty@gmail.com

NTAC-01 datasheet
ABB NTAC-01 OPTION/SP KIT; PULSE ENCODER INT 58919209

OPTION/SP KIT; PULSE ENCODER INT Contact:cassiebirthdayparty@gmail.com

CI854A datasheet
ABB CI854A PROFIBUS-DP/V1 interface 3BSE030220R1

PROFIBUS-DP/V1 interface Contact:cassiebirthdayparty@gmail.com

© Copyright : 2025 All Rights Reserved .

We are not an authorized distributor or representative of the brands/manufacturers featured on this website. Designated brand names and trademarks featured on this website are the property of their respective owners.

IPv6 network supported

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #