Products
Home ABB ABB A75-30-11 Contactor 1SBL411001R8411

ABB A75-30-11 Contactor 1SBL411001R8411

A75-30-11 Contactor

Contact:cassiebirthdayparty@gmail.com

  • Item NO.:

    ABB A75-30-11
  • Payment:

    T/T
  • Product Origin:

    Sweden
  • Shipping Port:

    HongKong
  • Lead Time:

    3 days
  • Goods Stock:

    10
  • Order(MOQ):

    1
  • Product Detail

ABB A75-30-11 Contactor 1SBL411001R8411

Contact:cassiebirthdayparty@gmail.com


SPECIFIC CAUTIONS (continued)

Page 76: Do not manipulate the locking device. ABB will take no responsibility for errors caused by manipulating locking devices.

-79 and Page 92: Do not place the internal back-up battery in the battery holder until the AC 800M Controller has been powered-up normally and the memory back-up function has been activated, that is, the Battery LED flashes. If no normal power supply is connected to the processor unit with the battery in place, then the CPU memory will immediately start to consume battery power.

Page 90: Note that in redundant CPU configuration, COM3 and the electrical ModuleBus on the baseplate can not be used.
Page 91: Note that the RCU Link Cable TK851 must be used and can not be replaced by a similar cable. Using another cable will disable the identification of the CPUs in the CB and Operator Station. When running in single configuration the RCU Link Cable TK851 might temporarily be used to perform the function of a termination plug.
Page 98: Do not connect the two CEX-Bus segments, separated with BC810, to each other with CEX-Bus extension cable TK850.
Page 98: In AC 800M High Integrity Controllers it is required that the external supply input of BC810 is connected and that the power supply is strictly configured either according to Figure 33 or according to Figure 34 and nor is it allowed to change the configuration by way of for instance individual circuit breakers between modules.

Page 99: Hot swap of the BC810 located next to a primary or single controller CPU, otherwise called “direct BC810”, might jeopardize the whole controller and should not be performed unless every module on the CEX-Bus are in a non-operating state. 

Note: In an AC 800M HI controller,this is unconditionally and intentionally leading to a shutdown of the controller.

Page 112: It is not possible to change the CI851 unit via hot swap and it is not allowed to perform an online upgrade of firmware in a system containing CI851.


ABB A75-30-11 Technical drawing:

ABB IMHSS05


We would be appreciate to receive your inquiry and also here are some other products for your choice:

6ES7318-3FL01-0AB0 1756-IF8  X20 BM 11
6ES7321-1BL00-0AA0 1756-OB8 X20 BC 0043-10
6AG1132-4BD02-7AA0 1756-BA1  X20 PS 9400
6AG1131-4BD01-2AA0 1769-L33ER X20 BB 80
6AG1132-4HB10-0AB0 1756-L82E X20bb22
6ES7153-2AR03-0XA0 1756-L73 X20ao4622
6GK1162-3AA0 1756-CN2R X20cp0292

ABB SPHSS05


Why Choose Us?

 Extensive & Real Inventory

Provide Satisfying Discounts

Fully Tested and Guaranteed

 We provide 12 months warranty for all parts and components.Your satisfaction is how we measure success.

 Flexible Payment & Shipment

Unless otherwise specified,we will ship your order via(DHL).We can also ship via Fedex.

Unparalleled Experience & Service

We cooperates with a great number of customers in numerous countries and regions around the world.Our customer support team is always on call to help you with any form of consultation.



Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
Ai815 datasheet
ABB AI815 Analog Input HART 8 ch 3BSE052604R1

Analog Input Module has 8 channels Contact:cassiebirthdayparty@gmail.com

Nmba-01 datasheet
ABB NMBA-01 3BHL000510P0003 Modbus Adapter Module

PLC Processor Module Contact:cassiebirthdayparty@gmail.com

FPBA-01 datasheet
ABB FPBA-01 PROFIBUS DP adapter module

ABB Profibus DP Adapter Module Contact:cassiebirthdayparty@gmail.com

RLM01 3BDZ000398R1 datasheet
ABB RLM01 3BDZ000398R1 PROFIBUS Redundancy Link Module

ABB PROFIBUS Redundancy Link Module Contact:cassiebirthdayparty@gmail.com

INIIT03 datasheet
ABB INIIT03 ABB Bailey Infi 90 Infi-Net Local Transfer Mod

Infinet to Infinet Transfer Module Contact:cassiebirthdayparty@gmail.com

PM864AK01 datasheet
ABB PM864AK01 Classic System 800xA hardware selector 3BSE018161R1

Classic System 800xA hardware selector Contact:cassiebirthdayparty@gmail.com

NTAC-01 datasheet
ABB NTAC-01 OPTION/SP KIT; PULSE ENCODER INT 58919209

OPTION/SP KIT; PULSE ENCODER INT Contact:cassiebirthdayparty@gmail.com

CI854A datasheet
ABB CI854A PROFIBUS-DP/V1 interface 3BSE030220R1

PROFIBUS-DP/V1 interface Contact:cassiebirthdayparty@gmail.com

© Copyright : 2025 All Rights Reserved .

We are not an authorized distributor or representative of the brands/manufacturers featured on this website. Designated brand names and trademarks featured on this website are the property of their respective owners.

IPv6 network supported

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #